Technology

Evaluating tele-refraction to address eye-care staffing gaps in Kenya

From the abstract: “The tele-refraction procedure entailed a trained technician performing objective refraction using the ClickCheck™ device, followed by subjective refinement under the real-time supervision of a remote optometrist via telecommunication.”

Internal fixation target as seen through the eyepiece of ClickCheck™, demonstrating the high-contrast radial pattern used for clarity judgment [22].
Internal fixation target as seen through the eyepiece of ClickCheck™, demonstrating the high-contrast radial pattern used for clarity judgment [22]. © 2026 Shadrack Muma and colleagues. PLOS ONE; original study · CC BY. Original figure preserved in a 16:9 frame and compressed; consult the full-resolution source for detailed labels.

Published in PLOS One on 2026-07-30, this study is presented as an attributed evidence briefing. The excerpts below are the original researchers’ words, reproduced under their Creative Commons Attribution licence. Health Signal has selected the abstract and, where needed, opening background paragraphs; the complete methods, results, limitations and references remain in the linked paper.

Original study title: Evaluation of a tele-refraction model to address the lack of human resources in Kenya

Original authors: Shadrack Muma, Jyoti Naidoo, Khathutshelo Percy Mashige, Tshubelela Sello Simon Magakwe

Source: PLOS One • DOI 10.1371/journal.pone.0352780

Read the complete primary study ↗ · Creative Commons Attribution licence

From the researchers

Abstract

Uncorrected Refractive Errors (URE) constitute a significant public health concern in Kenya, where limited availability of qualified eye care professionals continues to impede equitable access to refractive services. This shortage is particularly acute in rural and underserved regions, resulting in significant unmet visual health needs. The implementation of telemedicine; specifically, a tele-refraction model utilizing low-cost, portable devices, has emerged as a viable and cost-effective approach to decentralize service delivery, enhance accessibility, and mitigate the burden of URE at the primary healthcare level.

This non-inferiority diagnostic accuracy study was conducted in Machakos.

County, Kenya, to evaluate the performance of the OneSight EssilorLuxottica Foundation’s ClickCheck™ tele-refraction model in comparison with conventional face-to-face retinoscopy, which served as the reference (gold) standard. A total of 92 patients (184 eyes) were examined. The tele-refraction procedure entailed a trained technician performing objective refraction using the ClickCheck™ device, followed by subjective refinement under the real-time supervision of a remote optometrist via telecommunication. Statistical analyses assessed the agreement between the final subjective prescriptions obtained from both methods, focusing on the clinical conformity rate for spherical equivalent (SE), cylindrical power, and power vector components within a strict clinical tolerance limit of ±0.50 diopters (D).

The study demonstrated a high level of clinical concordance between the telerefraction model and the conventional gold-standard refraction method. The mean difference in spherical equivalent (SE) for objective refraction was minimal (+0.08 D), indicating negligible bias between the two techniques. Importantly, the final subjective prescriptions exhibited excellent clinical interchangeability, with 93.01% of cases falling within the ± 0.50D tolerance for SE and 94.41% within the same tolerance for cylindrical power magnitude. Furthermore, for clinically significant astigmatism, axis alignment showed complete conformity within the 10 degrees tolerance range across all cases.

The tele-refraction model using the ClickCheck™ device, combined with remotely guided subjective refraction, demonstrated accuracy, reliability, and non-inferiority when compared with conventional in-person refraction. These findings substantiate the clinical validity of tele-refraction, which holds the potential to mitigate the acute shortage of eye care professionals and to enhance equitable access to refractive error correction services among underserved populations in Kenya.

Background

It is estimated that more than six million individuals in Africa live with uncorrected refractive errors, predominantly in remote, socioeconomically disadvantaged, and rural communities [1]. In Kenya, where approximately 71% of the 47 million inhabitants reside in rural areas, access to refractive error services remains critically limited. Only an estimated 10–20% of those requiring vision correction can obtain and afford such services [2]. Although no comprehensive population-based studies on refractive errors have been published in Kenya, existing estimates suggests that approximately 6.39% of the population is affected by uncorrected refractive errors (3). Moreover, prevalence rates reported from underserved rural districts range from 5.2% to over 17.2% [3].

Reading this evidence

Use the full paper to check the study design, participant selection, comparator and outcome definitions before drawing a practical conclusion. An association does not by itself show cause and effect. A reported performance measure needs its denominator and uncertainty. A finding from a particular facility, sample or time period should retain that scope when it is discussed elsewhere.

This briefing makes the source accessible within the wider technology & industry desk. It does not assess an individual patient or certify a product. When considering relevance to another health system, examine the original authors’ account of context and limitations, then seek local implementation evidence. The related reporting below provides other studies to read alongside this one; it is a topic connection, rather than a claim that their results are directly comparable.

© 2026 Shadrack Muma, Jyoti Naidoo, Khathutshelo Percy Mashige, Tshubelela Sello Simon Magakwe. Excerpts reproduced under CC BY. Selection, formatting and contextual notes by Health Signal. The researchers are the authors of the source study, not members of Health Signal’s staff.

Explore connected evidence

Health Signal Editorial Desk

Health Signal’s publication desk curates source-based health analysis and attributed research briefings. Study authors and originating institutions are credited within each article. Preparation used AI assistance; source and licence checks do not constitute independent replication or clinical endorsement.

More from this writer ↗